ProOperator
ART. NO: 5652025 5000
SIZES: EUR 36-48
Find my sizeIt is essential that the operator knows where and for what the boots protect. The black parts clearly identifies protective areas, and the label tells the level of protection. White label indicates protection for 300 bar/4 350 psi single jet, 500 bar/7 500 psi rotor jet and 500 bar/7 500 psi flat jet – 3/5/5.
How to read the test results: There is no international standard for the testing of protection levels. Therefore the testing can differ significantly between companies. For this reason it is crucial to be aware of the differences and how and what to properly compare. A protection level of eg. 3 000 bar can mean different things, depending on the pressure, flow, nozzle, distance or speed used while testing. To verify the protective qualities we have chosen the most common working conditions when performing our tests of notified body.
Most nozzles perform at their best between 50 and 100 mm, therefore we have chosen the distance of 75 mm. Rotating tests have been performed with two nozzles (adding more nozzles result in a lower overall impact).
Note! Different values, eg. pressure, flow, nozzle, distance or speed, can give significantly different results!
Product Category | Pressure, Bar | Pressure, psi | Flow, Litre/minute | Flow, Gallon/minute | Nozzle, Type | Nozzle, Quantity | Nozzle, Diameter mm | Nozzle, Diameter in. | RPM, Revolutions per minute | Distance, mm | Distance, in. | Linear speed, m/s | Linear speed, in./sec | Result |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ProOperator | 300 | 4350 | 13.1 | 3.5 | Single | 1 | 1.1 | 0.04 | - | 75 | 3 | 0.5 | 20 | No penetration |
ProOperator | 500 | 7500 | 16.9 | 4.5 | Rotor | 1 | 1.1 | 0.04 | 3000 | 75 | 3 | 0.5 | 20 | No penetration |
ProOperator | 500 | 7500 | 16.9 | 4.5 | Flat | 1 | 1.1 | 0.04 | - | 75 | 3 | 0.5 | 20 | No penetration |
All of our personal protective equipment is CE-labelled in accordance with Regulation (EU) 2016/425. TST Sweden is certified in accordance with ISO 9001:2015 and ISO 14001:2015 – important tools for ensuring the quality of our products and our work to lay the foundation for positive environmental development.
Declaration of ConformityWash the boots regularly with lukewarm soapy water. Avoid solvents and scrubbing with a coarse brush. Allow to dry at room temperature and avoid contact with heating radiators. Store the boots upright in a cool dark place. For rubber surface care of the boots, we recommend silicon oil or glycerine.
Boots exposed to affect its protective ability must be rejected.
EUR | US | UK |
---|---|---|
36 | 4 | 3 |
37 | 5 | 4 |
38 | 5 ½ | 4 ½ |
39 | 6 ½ | 5 ½ |
40 | 7 ½ | 6 ½ |
41 | 8 ½ | 7 ½ |
42 | 9 | 8 |
43 | 10 | 9 ½ |
44 | 10 ½ | 10 |
45 | 11 ½ | 10 ½ |
46 | 12 | 11 |
47 | 13 | 12 |