WSS
ART. NO: 5850012 5000
SIZES: Pcs
How to read the test results: There is no international standard for the testing of protection levels. Therefore the testing can differ significantly between companies. For this reason it is crucial to be aware of the differences and how and what to properly compare. A protection level of eg. 3 000 bar can mean different things, depending on the pressure, flow, nozzle, distance or speed used while testing.
Note! Different values, eg. pressure, flow, nozzle, distance or speed, can give significantly different results!
HIGH PRESSURE WATER JET TEST
| Product | Pressure, Bar | Pressure, psi | Flow, Litre/minute | Flow, Gallon/minute | Nozzle, Type | Newton | Distance, m | Distance, ft | Result |
|---|---|---|---|---|---|---|---|---|---|
| Booth | 1100 | 16 000 | 100 | 26.4 | Single | 740 | 2.3 m | 7.5 ft | No penetration |
| Booth | 3000 | 43 500 | 43 | 11.4 | Single | 550 | 1.5 m | 5 ft | No penetration |
PROJECTILE TEST
| Projectile | Linear speed, m/s | Linear speed, ft/sec | Number of textile layers | Result | ISO Standard |
|---|---|---|---|---|---|
| Steel bullet, 6 mm | 120 | 393.7 | 1 | No penetration | EN ISO 168 |
| Stone short, 360 g | 13 | 42.7 | 1 | No penetration | EN ISO 1794-1 |